Campus-Wide Single-Phase UPS Service

Know the condition of every UPSbefore the next outage.

One coordinated program for inspection, documentation, battery replacement, and installation of new UPS systems across every campus building — so Facilities and IT have a reliable equipment inventory, clear risk priorities, and a practical replacement plan instead of an after-hours emergency.

★  Authorized dealer — APC by Schneider Electric & Eaton
🛡  SDVOSB — Service-Disabled Veteran-Owned Small Business
🏫  One program across every campus building
The Problem

Distributed equipment, invisible risk.

Single-phase UPS systems are scattered across every kind of campus building — and no one owns the full picture.

AcademicAdministrativeHealthCareSecurityTechnology

Phasor closes the gap. We physically inspect each UPS and record it on a standardized Campus UPS Data Sheet — turning scattered, unmanaged equipment into a single accountable inventory.

Without a centralized program, problems compound quietly:

  • Aging batteries quietly lose runtime until they can't carry the load.
  • Overloaded units run past capacity with no headroom for growth.
  • Active alarms chirp away in closets nobody visits.
  • Outdated systems age out of support and spare parts unnoticed.
  • …until critical equipment loses power — and it becomes an emergency.
The Program

Inspect. Document. Replace — on a plan.

Phasor physically inspects each UPS and records it on a standardized Campus UPS Data Sheet. The resulting inventory gives Facilities and IT a practical view of system condition, risk, and future replacement needs.

01

Inspect & Test

Evaluate operating condition, alarms, load, voltage, runtime, batteries, room environment, and UPS airflow.

02

Document & Prioritize

Create a standardized equipment record with practical observations and recommended action dates.

03

Replace & Install

Replace batteries, or supply and install a correctly sized new UPS — only when the data shows it is needed.

Annual Service Contract

Two preventive walkthroughs, every year.

During each visit, Phasor updates the UPS data records, gives feedback on room and environmental conditions, records room temperature, and cleans the UPS fan area and air intake to promote maximum airflow. We also document repairs the room needs — a cooling unit leaking water, for example — so Facilities and IT can address conditions that threaten equipment reliability before they cause a failure.

1

Survey the campus

Locate and inspect every participating single-phase UPS.

2

Build the data set

Document condition, load, runtime, batteries, and environment.

3

Prioritize action

Identify immediate failures and schedule planned replacements.

4

Complete the work

Replace batteries and install new UPS systems where needed.

The Campus UPS Data Sheet

17 points that turn scattered equipment into an actionable plan.

A data sheet is completed for every walkthrough. Together, these points identify immediate risk, confirm performance, and establish a defensible replacement timeline.

01

Building

Which campus building the UPS is in, so every unit is tracked by facility.

02

Room Location

The specific room, closet, lab, or equipment area, so the UPS is found fast.

03

UPS Model

Manufacturer and model — capacity, specs, batteries, parts, and service needs.

04

Serial Number

The unique identifier for warranty research, service history, and support.

05

UPS Age

Approximate equipment age to evaluate reliability and replacement timing.

06

Alarm Status

Active alarms, warning messages, or fault codes requiring attention.

07

Load Percentage

How much capacity is in use — whether the system is sized right or near its limit.

08

Load in Watts

The actual connected load — a precise measure of what the unit supports.

09

Battery Runtime

Estimated time the UPS can carry the connected load during an interruption.

10

Input / Output Voltage

Confirms the UPS is receiving and delivering the correct voltage.

11

Battery Install Date

A reliable starting point for tracking installed-battery service life.

12

Battery Age

Supports planned replacement before runtime and reliability decline.

13

Self-Test Result

Pass or fail — may reveal weak batteries or an internal UPS problem.

14

UPS Replacement Date

Recommended by age, condition, support status, parts availability, and use.

15

Battery Replacement Date

Set by age, condition, testing, and available runtime.

16

Environmental Notes

Heat, dust, moisture, restricted airflow, or blocked ventilation that shortens life.

17

UPS Notes

Overall condition, unusual sounds, install concerns, and service recommendations.

The data becomes your maintenance & capital-planning tool.

Campus personnel get a clear picture of which systems are healthy, which batteries are approaching replacement age, and which units need immediate attention. When replacement is required, Phasor supplies and installs the correctly sized UPS, replaces battery cartridges, removes failed or obsolete equipment, and recycles old batteries properly.

Get Started

Replace emergencies with a campus-wide plan.

Start with a complete inventory and condition assessment.